Chemical Industry Cases
Chemical Industry Cases

Chemical Industry Cases

2026-03-10

Event: During routine data monitoring, an analyst observed a sudden increase in vibration in a pump-motor unit and investigated it.

 

 

Analysis conclusion: Significant energy at 50 Hz and 100 Hz was observed in the X direction at the non-output ends of the pump and motor. As the pump motor was a two-pole motor, the analyst suspected shaft misalignment.

 

 

Site verification: After receiving the analysis, the customer promptly inspected the pump-motor unit. Coupling misalignment was confirmed as the cause of a torque-related fault, which could have progressed to seizure if it deteriorated further.

Return

Contact us for professional solutions