Shenzhen Qianhai Huilian Technology Development Co., Ltd. is headquartered in Shenzhen's national-level free trade zone, Qianhai New Area. It holds certifications as a National High-Tech Enterprise and a National Specialized and Innovative "Little Giant" enterprise. The company has branches in Beijing, Shanghai, Hefei, Chengdu, Xi'an, Changchun, and Urumqi.
Learn More

2016

Year Established

20 +

Invention Patents

1000 +

Enterprises Served

200000 +

Equipment Units Monitored

Customer Cases

  • Wind Power Cases Wind Power Cases
  • Nuclear Power Cases Nuclear Power Cases
  • Chemical Industry Cases Chemical Industry Cases
  • Coal Mining Cases Coal Mining Cases
  • Thermal Power Cases Thermal Power Cases

Customer Cases

  • Event: Radial vibration at the rear bearing of the gearbox high-speed shaft exceeded the limit and reached the high-alarm level. Site personnel requested diagnosis.

    Site verification: After we communicated the results, the customer inspected the gearbox with a borescope and confirmed severe gear damage. The gearbox was subsequently replaced.
  • Event: Site personnel reported slightly elevated motor vibration and requested diagnosis of the unit.

    Site verification: The motor was realigned during scheduled maintenance, after which vibration returned to the normal range.
  • Event: During routine data monitoring, an analyst observed a sudden increase in vibration in a pump-motor unit and investigated it.

    Site verification: After receiving the analysis, the customer promptly inspected the pump-motor unit. Coupling misalignment was confirmed as the cause of a torque-related fault, which could have progressed to seizure if it deteriorated further.
  • Event: Vibration at the air compressor motor measurement point began increasing slowly in early August. Noise was noticeably greater than that of motors of the same model. Maintenance personnel could not identify the cause and requested our analysis.

    Site verification: Maintenance personnel immediately replaced the air compressor bearing and confirmed severe wear.
  • Event: A steam turbine unit at a thermal power plant started on September 24. On September 28, shaft vibration at Bearing No. 1 suddenly increased and began fluctuating, triggering an abnormal alarm. Site personnel requested diagnosis and recommendations.

    A detailed inspection found slight deposits and minor deformation in stationary parts of the steam seals and oil deflectors, resulting in insufficient local rotor–stator clearance. After correction, the unit was restarted and connected to the grid. Shaft vibration at Bearing No. 1 stabilized within the normal operating range, irregular fluctuations disappeared completely, and 1×/harmonic vibration energy and phase changes returned to stable levels. Equipment operation returned to good condition.
Let's explore the future together!

We not only provide job opportunities, but also help you grow and leap forward. We always practice and respect talents, and are committed to creating a humane organizational environment and atmosphere. Make every member professional, dedicated, and happy. Hurry up and join us, and together we will compose a brilliant symphony!